MGC 25 |
MGC 50 |
MGC 100 |

MGC 150 |

MGC 300 |

MGC 350 |
| Features |
Auto Start |
- AC metering
- Phase selector switch
- Hourmeter
- Compact enclosure – horizontal style
- Optional current transformers
|
- Cascade controller
- AC voltmeter
- Hourmeter
- Power on-off switch (toggle)
- Small enclosure
|
- Cascade controller
- Gages for oil pressure and water temperature (mechanical or electric), compatible with Murphy or VDO senders
- AC metering – volts, amps, hertz
- Phase selector switch (3 phase)
- Hourmeter
- Power on-off switch (toggle)
|
- Cascade controller
- Provision for optional PVA gages or PowerView
- Quick disconnect (MEH harness required)
- AC metering – volts, amps, hertz
- Phase selector switch (3 phase)
- Hourmeter
- Power on-off switch (toggle)
|
- iGUARD controller
- Volts adjust potentiometer
- Speed adjust potentiometer
- Run/idle switch
- E-stop
- Basic I/O wired to terminal strip
|
- iGUARD controller
- Relay board
- Quick disconnect
- All I/O wired to terminal strip
- Volts adjust potentiometer
- Speed adjust potentiometer
- Run/idle switch
- E-stop
- Oversized enclosure
|
Manual Start |
MGC 50 |
MGC 100 |
MGC 150 |
MGc 300 |
MGC 300 |
- Start method (choose one)
- Key start module with first out annunciation (removes power switch)
- Key switch with 518 Tattletale
- Key switch with pre-heat & 518 Tattletale
- Push button with 518 Tattletale
- Voltmeter
- Hourmeter
- Small enclosure
|
- Start method (choose one)
- Key start module with first out annunciation (removes power switch)
- Key switch with 518 Tattletale
- Key switch with pre-heat & 518 Tattletale
- Push button with 518 Tattletale
- Gages for oil pressure and water temperature (mechanical or electric), compatible with Murphy or VDO senders
- AC metering – volts, amps, hertz
- Phase selector switch (3 phase)
- Hourmeter
- Power on-off switch (toggle)
|
- Start method (choose one)
- Key switch with 518 Tattletale
- Key switch with pre-heat & 518 Tattletale
- Push button with 518 Tattletale
- PowerView
- Quick disconnect (MEH harness required)
- AC metering – volts, amps, hertz
- Phase selector switch (3 phase)
- Hourmeter
|
|
|
Options |
MGC 50 |
MGC 100 |
MGC 150 |
MGc 300 |
MGC 300 |
|
Note: Minimal options available due to enclosure space constraints – consult IPD for availability |
- DC voltmeter, DC ammeter
- Relays for alarm outputs
- NEMA 4 enclosure
- Electric senders – 100 PSI & 250F, ½ inch or M14 port
- Electric senders - 100 PSI & 320F, M14 port (Deutz engines)
- Quick disconnect and wiring harness
- Energized to stop (auto start only)
- E-stop (mushroom style)
- Phase selector switch (single phase applications)
- Current transformers
|
- PowerView
- PVA gages – oil pressure, water temp, DC volts, tachometer
(select up to 3)
- MEH wiring harness
- Relays for alarm outputs
- NEMA 4 enclosure
- Delete quick disconnect
- E-stop (mushroom style)
- Current transformers
- Phase selector switch (single phase applications)
|
- Misc. senders and end devices
- MEH wire harness
- Remote relay board(s)
- Remote annunciator(s)
- Current transformers
- NEMA 4 enclosure
- Expanded alarms and shutdowns
- Custom text for digital inputs
- Custom splash screen
- Display heater for operation down to -40C
|
- Misc. senders and end devices
- PVA gages
- MEH wire harness
- Remote relay board(s)
- Remote annunciator(s)
- Current transformers
- NEMA 4 enclosure
- Expanded alarms and shutdowns
- Custom text for digital inputs
- Custom splash screen
- Display heater for operation down to -40C
|