The LC10 is a rugged, displacer-operated liquid level controller that is ideal for use on scrubbers, separators, heater treaters or anywhere else liquid level control is needed. Its industry-proven, force-balance design allows for control of gas/liquid as well as liquid/liquid interfaces.
FW Murphy is the exclusive BMD distributor for new equipment packages.
Sizes:
Threaded: 1 1/2” and 2”
Flanged: 2” to 8”
Union: 4” and 5”
Pressure Rating:
Threaded: 6000 psi
Flanged: Up to ANSI 2500 class
Union: 1500 psi
Temperature Range:
-50° F to 400° F (-46° C to 204° C) (varies by material selections)
Pilot Connections: 1/4” NPT
Pilot Max Pressure: Limited by gauges
Electric Switch Ratings:
SPDT: 15 A @ 125, 250, 480 VAC
DPDT: 10 A @ 125 VAC
Materials:
Body: A105, LF2 (low temp option), SST
Body Trim: 303 stainless and 316 stainless (optional)
Pilot Body: Aluminum
Pilot Trim: 303 stainless
Case: Aluminum
Case Internals: 303 stainless
Displacer: PVC (standard), acrylic, stainless